Data Acquisition Expansion Pod 1
Data Acquisition
Expansion Pod
Users Guide
Contents
Chapter 1: Introduction ................................................. 2
Physical Description ...........................................................................2
DAQPod Features ..............................................................................2
Chapter 2: Before Connecting the Data Acquisition
Expansion Pod ............................................................... 3
Compatible Data Acquisition Cards ....................................................3
Recommended Mating Connector ......................................................3
Understanding Signal Differences from Standard E Series Devices ..3
NI DAQCard signals not available with the DAQ
Expansion Pod ......................................................................4
Sensor excitation .........................................................................4
Chapter 3: Connecting the Expansion Pod ................. 6
Connector Diagram and Pinout Chart ................................................6
Recommended Software to Gather and Analyze Data .......................7
Chapter 4: Finding More Information ........................... 9
Chapter 5: Signal Descriptions .................................. 10
I/O Connector Signal Descriptions ..................................................10
Chapter 6: Configuration Switches ............................ 15
Default Switch Settings ....................................................................15
Configuring Switches ........................................................................16
Continuously enable the Sensor Excitation Output ...................16
Use DIO7 to enable/disable Sensor Excitation Output ..............17
Bypass the Sensor Excitation (Output Analog Out 0 rather than
the Sensor Excitation) .........................................................17
Enable current limit monitoring ..................................................18
Disable current limit monitoring and reconnect the PFI5 signal
to the 50-pin connector .......................................................18
Locating Switches on the Schematic ................................................19
Appendix: DAQ Expansion Pod Schematic ............... 20
Zobrazit stránku 0
1 2 3 4 5 6 ... 27 28

Shrnutí obsahu

Strany 1

Data Acquisition Expansion Pod 1Data Acquisition Expansion Pod™User’s GuideContentsChapter 1: Introduction ...

Strany 2 - Chapter 1: Introduction

10 User’s Guide I/O Connector Signal Descriptions The following table describes the signals found on the I/O connectors. The information is based

Strany 3 - Acquisition Expansion Pod

Data Acquisition Expansion Pod 11Signal nameReference Direction DescriptionStandard National Instruments E Series DAQCard SignalsAI SENSE— Input

Strany 4 - Sensor excitation

12 User’s Guide Signal nameReference Direction DescriptionPFI 1/AI REF TRIGD GND Input PFI 1—As an input, this pin is a PFI.Output AI Reference

Strany 5

Data Acquisition Expansion Pod 13Signal nameReference Direction DescriptionPFI 5/AO SAMP CLKD GND Input PFI 5—As an input, this pin is a PFI.Out

Strany 6 - 6 User’s Guide

14 User’s Guide Signal nameReference Direction DescriptionCTR 0 OUTD GND Output Counter 0 Output Signal—As an output, this pin emits the Ctr0Int

Strany 7

Data Acquisition Expansion Pod 15The configuration switches in the DAQ Expansion Pod let you configure how the pod functions. This chapter describes

Strany 8 - 8 User’s Guide

16 User’s Guide The chart below shows the name and default setting of each switch. Switch # Switch Name Default Setting1I_FLAG OFF2PFI5_OUT ON3OPA

Strany 9

Data Acquisition Expansion Pod 17Switch # Name Setting Result3 OPA_EN_H OFF Sensor Excitation control is enabled continuously4 DIO7_OUT ON5 SENSOR

Strany 10 - 10 User’s Guide

18 User’s Guide Switch # Switch Name Switch SettingsResult3 OPA_EN_H OFF Sensor Excitation control is enabled continuously 4 DIO7_OUT ON5 SENSOR_E

Strany 11

Data Acquisition Expansion Pod 19Locating Switches on the SchematicThe Appendix shows a five-page schematic. The schematic provides an in-depth vie

Strany 12 - 12 User’s Guide

2 User’s Guide Chapter 1: IntroductionThe Allegro CX™, combined with the Data Acquisition Expansion Pod™ (“DAQ Expansion Pod™”), places the functi

Strany 13

20 User’s Guide Appendix: DAQ Expansion Pod SchematicThe next five pages shows the schematic used to build the DAQ Expansion Pod. The following tab

Strany 14 - 14 User’s Guide

Data Acquisition Expansion Pod 21

Strany 15 - Default Switch Settings

22 User’s Guide    

Strany 16 - Configuring Switches

Data Acquisition Expansion Pod 23   

Strany 17

24 User’s Guide 

Strany 18 - 18 User’s Guide

Data Acquisition Expansion Pod 25

Strany 21 - 

28 User’s Guide 1132 West 1700 North Logan, UT 84321 USATel +1 435.753.1881Fax +1 435.753.1896Email [email protected] www.junipersy

Strany 22 - 22 User’s Guide

Data Acquisition Expansion Pod 3Chapter 2: Before Connecting the Data Acquisition Expansion PodThis chapter contains instructions for connecting t

Strany 23 - 

4 User’s Guide rugged environmental seal. The connector’s large size makes wiring easy, and its universal design lets you integrate a variety of t

Strany 24 - 24 User’s Guide

Data Acquisition Expansion Pod 5CAUTION: Damage can occur to the Allegro CX or NI DAQCard if these constraints are not followed.The output voltage

Strany 25

6 User’s Guide Chapter 3: Connecting the Expansion PodThis chapter provides the following:A diagram of the 50-pin D connector A chart with pinout

Strany 26

Data Acquisition Expansion Pod 7Row 1 Row 2 Row 31 – DGND 18 – GPCTR0_OUT 34 – FREQ_OUT2 – PFI8 19 – PFI7 35 – PFI63 – PFI9 20 – GPCTR1_OUT 36 – P

Strany 27

8 User’s Guide Article: “What is the LabVIEW PDA module?” Site: http://www.ni.com/labview/what_is_pdaArticle: “Build Rugged Mobile Test Instrument

Strany 28 - HarvestMaster

Data Acquisition Expansion Pod 9To find more information about the DAQ Expansion Pod, the Allegro CX, NI DAQCards, LabVIEW, or LabVIEW PDA, use the